Analysis Software |
|
|
Biometrics NEW V7 Analysis
Software for
-
DataLOG W4X8 (Wireless)
-
DataLOG P3X8 (USB)
-
DataLINK DLK900
|
|
|
|
| |
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
The
Biometrics Analysis Software is now an even more
comprehensive tool for EMG, Goniometer and associated
sensor analysis.
|
|
|
|
| |
|
Two major
NEW key features have been added in version 7.
Create and save
Workspaces. A Workspace is the complete appearance of the
application along with the settings used within the program. This
includes:
o
The names
of all open data files
o
The
position and size of all windows
o
The
position, size and appearance of all application
toolbars and tool windows
o
Application
preferences and options
o
All markers
and filters
o
All zoom
and scroll settings
Multiple
workspaces may be saved. In addition, when the
application is closed, the current complete workspace is
automatically saved in a file called “Workspace when
last closed”.
The
workspace with the associated data files may be saved as
a ZIP file which can be extracted using many third party
applications. This facilitates electronic mailing of the
data analysis results. |
|
|
 |
|
| |
|
The new
Expanded Results
Table showing all results of all channels simultaneously. Multiple
traces/graphs/windows from a single file or from multiple files may be
compared. The spreadsheet style table displays the following data
for each trace: |
|
|
|
|
|
|
|
|
|
o
File Name
o
Channel
number
o
Trace Title
o
Filters used
o
Scientific
Units
o
Start time in
hrs:minutes:seconds.mS
o
End time in
hrs:minutes:seconds.mS
o
Time Span
o
Top marker
(if applied) in engineering units
o
Bottom Marker
(if applied) in engineering units
o
Difference
Marker
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
o
Over
Excursions – number of excursions over the Top marker. The minimum time
above the marker to count as an excursion is set by the user with a
default value of 0.1 seconds
o
Under
Excursions – number of excursions below the Bottom marker. The minimum
time below the marker to count as an excursion is set by the user with a
default value of 0.1 seconds
o
Start Value
for time markers
o
End Value for
time markers
o
Difference/sec for the marked time
|
|
|
|
|
o
Trend –
calculated using Linear Regression Analysis
o
Maximum Value
o
Time to
Maximum
o
Minimum Value
o
Time to
Minimum
o
Mean Value
o
Repetitions
The Expanded Results Table
may be copied to the clipboard and pasted into other applications, such
as MS Excel, for further analysis and printing of results.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
OTHER FEATURES INCLUDE: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
-
Open an unlimited
number of data files with the option to track the time axis across
all files allowing display and analysis for a large number of
channels.
-
Waveform display in
multiple windows and formats with full zoom, scroll, and area
marking facilities, option to split, tile and cascade windows.
-
Waveforms within the
same window may be viewed overlaid or as separate traces. Easily
toggle between the two views with a simple keystroke.
-
Engineering units with
custom scaling ability on all traces independently.
-
Each recorded file is
data and time stamped.
-
Full trace management
(change line width, colour, background colour, etc.)
-
Ability to set an
unlimited number of vertical cursors (time markers) to a single
trace, all traces in a window, and across multiple windows giving
total flexibility. All values are shown simultaneously in the
expanded results table.
o
All vertical
cursors may be altered via expanded results table by typing in time
values to 0.001S giving maximum control.
o
All
horizontal cursors may be altered via expanded results table by typing
in Y value to 0.01 giving maximum control.
-
Filters
o
Up to six
filters may be applied to each trace
o
Copy filters
set to a channel to all other channels in 1 simple operation
o
A memory
store & recall (2 memory settings) for the filters set to a channel to
easily be applied to any other channel. These memory settings are kept
stored indefinitely until changed by the user
o
Filters
include:
|
o
Rectify |
o
Integrate |
o
EMG
Work Done (new in v7) |
|
o
Average |
o
Offset |
o
LPF 1st
Order (new in v7) |
|
o
RMS |
o
Scale |
o
Acceleration (new in v7) |
|
o
Velocity |
o
Mean
Frequency |
o
Median Frequency |
-
Versatile Data Export
for import into other applications for further analysis
o
ASCII export
of raw data
o
ASCII export
traces after filters have been applied in engineering units
o
Wave file
format
-
Expanded ability to
include text notes with data files
-
Power Spectrum Graph
-
X-Y graphs
-
FFT high pass filters:
remove DC, remove very low frequencies
-
FFT window functions:
|
o
Rectangle/Flat top |
o
Blackmann standard |
o
Hamming |
|
o
Triangle/Bartlett |
o
Blackmann Opt |
o
Hann |
-
Comprehensive Help menu
that may be used as a tutorial for both the hardware and software
operations.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|

Display of Workspace containing unfiltered
EMG data (abdominal muscles) with Goniometer data (hip
flexion/extension) and EMG Power Spectrum. |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
As soon as a file is opened it is displayed as a raw EMG
file and may then be subject to any or all of the features listed above.
The data may be left as a whole or truncated into smaller files of
specific data for further analysis. Of course not only EMG data
may be displayed at any one time. The Y axis may be labelled with
any units governed by what sensors where connected at the time of
recording, e.g. Kg or lbs for force or degrees for limb movement.
These units are then saved with the file and automatically compute every
time the file is reopened.
The digital inputs are
displayed on a separate graph to the analog inputs. Using this
facility during gait analysis, toe and heel contact and off may be obtained using the contact
switch assembly type no. FS4. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|

Help Menu for DataLOG W4X8 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|

Data Export options |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Top of Page |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|