Unique Solutions for Clinical And Research Applications - Biometrics Ltd

Research Using Biometrics Ltd Sensors and Instrumentation
for Upper Extremity Measurements

keywords: EMG SX230 Goniometers SG65 workplace analysis UE 2010

Comparison between Direct Measurement and Observation Methods for Upper Extremity Activity Assessment at Workplace; YT Chen, CY Chen, HW Liang, TR Chang, YH Hwang; Journal Of Occupational Safety and Health 18:p1-14 2010; Biometrics Ltd EMG used to monitor activities of extensor digitorum communis (EDC) and flexor digitorium superficialis (FDS) during various hand activities while the Biometrics Ltd goniometer simultaneously measured the wrist movement and number of repetitions.

keywords: DataLINK Goniometers EMG Stroke Spasticity Botulinum Toxin elbow wrist UE 2009

Quantitative Measurement of Poststroke Spasticity and Response to Treatment with Botulinum Toxin a 2 Patient Case Report; E Cousins, A B Ward, C Roffe, L D Rimington, A D Pandyan; Physical Therapy Volume 89 Number 7 p688-697; Biometrics Ltd DataLINK, Goniometers and EMG sensors used as a neurophysiological measure of joint angle and EMG activity in post stroke patients treated for spasticity with Botulinum toxin.

keywords: Dynamometer Pinchmeter DataLINK grip strength UE 2009

Conservative vs Operative (Fixation with K-wires) Treatment of Isolated Fractures of Metacarpal bones - Results of the Prospective, Randomized Study; A Zyluk, T Budzynski; Polski Przeglad Chirurgiczny, 2009, 81, 5, 217-224; Biometrics Ltd Dynamometer and Pinchmeter used with a Biometrics Ltd DataLINK to measure grip and pinch strength in metacarpal fracture patients, comparing those who had surgery (K-wire fixaton) with those patients who were treated more conservatively by reduction and immobilization.

keywords: ACL 300 accelerometers finger kinesiology UE 2008

A technique to determine friction at the fingertips; A Browne, J Healy, L O’Sullivan; J Appl Biomech 2008 Feb 24(1) 43-50; Biometrics ACL300 used to measure slip force of an object as it was dropped.

keywords: DataLink EMG Goniometers wrist ergonomics UE 2008

Endoscopic Ultrasound Device Assessment Using an Integrated Ergonomics Analysis System for Wrist Posture and Force; A Browne, J Healy, L O’Sullivan; University Of Limerick Ireland; Healthcare Systems Ergonomics and Patient Safety (HEPS) Conference, Strasbourg, June 25-27, 2008; Biometrics Ltd DataLINK, goniometers, and EMG were used to record wrist posture and forearm muscle activity in simulated endoscopy procedure.

keywords: DataLINK EMG SX230 UE 2008

Manifestation of Fatigue in Myoelctric Signals of Dynamic Contractions Produced During PC Games; MA Oekoei, H Hu and JQ Gan; University Of Essex, UK; 30th Annual International IEEE EMBS Conference Vancouver, Canada, August 20 -24 2008; Biometrics Ltd SX230 electrodes used to measure muscle activity in four locations on forearm to measure whilst playing computer games.

keywords: EMG SX230 UE robotic arm control 2008

Artificially Controlling the Limb Movement of Robotic Arm Using Machine Interface with EMG Sensor; GS Patel, A Rai, S Prasad; Sensors and Transducers Journal March 2008, vol 89, issue 3, pg 39-51; The aim of this paper is to describe a human machine interface using Electomyogram (Biometrics Ltd SX230 EMG sensors) signal to artificially control the limb movement.

keywords: Goniometer SG65 Torsiometer Q150 Ergonomic risk Saw mill workers UE 2007

Comparison of Ergonomic Risk Assessment Output in a High Risk Sawmill Occupation: Saw Filer; T Jones, S Kumar; NORA Proceedings 2007 p103 -110; Biometrics Ltd Goniometer and Torsiometer used to measure motion of the wrist and forearm whilst subjects hammered saws.

keywords: Gonio finger F35 elbow UE stroke research 2007

Exaggerated interlimb neural coupling following stroke; T Kline, B Schmidt, D Kamper; Brain 2007, 130(1):159-169; Joint angles of the digits of the impaired hand and angle measurements of the elbow joint on the impaired side were measured with Biometrics Ltd electrogoniometers in this study of patterns of interlimb coupling in ten stroke survivors with chronic hand impairment.

keywords: Gonio SG65 EMG SX230 UE wrist elbow ergonomics in surgery 2007

Effect of handle design and target location on insertion and aim with a laparoscopic tool; A Trejo, MC Jung, D Oleynikov, MS Hallbeck; Applied Ergonomics 2007, 38: 745-753; One of the main ergonomic problems associated with laparoscopy is the surgeon’s non-neutral position during surgery. The objective of this study was to evaluate a laparoscopic tool design by examining the effects of hand posture, target position and monitor angle on physical workload and operation efficiency during both insertion and aim tasks. Biometrics Ltd electrogoniometers wre used to measure wrist and elbow position.  Biometrics Ltd EMG sensors were used to measure muscle activity in forearm and upper arm muscles.

keywords: Gonio SG110 thumb UE ergonomics 2007

Accuracy and feasibility of using an electrogoniometer for measuring simple thumb movements; P Jonsson, P Johnson, M Hagberg; Ergonomics 2007, vol 50, issue 5, pg 647-659; The aim of this study was to determine the accuracy and feasibility of using a Biometrics Ltd electrogoniometer for measuring simple thumb movements and concluded that electrogoniometers have utility for studying thumb movements during mobile phone use and may be used to evaluate other thumb-based input devices.

keywords: Goniometer Carpal Tunnel Syndrome wrist elbow UE 2006

Longitudinal Excursion and Strain in the Median Nerve During Novel Nerve Gliding Exercises for Carpal Tunnel Syndrome; M W Coppieters, A M Alshami; Journal Of Orthopaedic Research 2006 24 p1-9; Biometrics Ltd goniometers used to measure wrist and elbow joint position and movement in cadavers during testing of novel nerve gliding techniques.

keywords: Goniometer pain hand UE 2006

An Experimental Pain Model to Investigate the Specificity of the Neurodynamic Test for the Median Nerve in the Differential Diagnosis of Hand Symptoms; M W Coppieters, A M Alshami, P W Hodges; Arch Phys Med Rehabil Vol 87 October 2006; Biometrics Ltd goniometer used to accurately document elbow positions during neurodynamic testing in subjects with induced hand pain.

keywords: Gonio elbow XM110 UE motor control OT perception 2006

The effects of contextual relevance and ownership on a reaching and placing task; M Holubar, m rice; Australian Journal of Occupational Therapy 2006, 53:35-42; This study aimed to maintain the purposefulness of the occupation – the entire movement of placing the coffee mug on the shelf.  The data were collected by using a Biometrics Ltd electronic goniometer attached across the elbow of the dominant limb.

keywords: Gonio wrist UE work evaluation ergonomics 2006

Increasing the degree of automation in a production system: Consequences for the physical workload; I Balough, K Ohlsson, GA Hansson, T Engstrom, S Skerving; International Journal of Industrial Ergonomics 2006, 36:353-365; Biometrics Ltd electrogoniometers were used for measuring work postures and movements of the wrists of production line workers in a company processing wooden boards for parquet flooring.

keywords: Gonio G35 finger mcp UE neuro stroke 2005

Motor Impairment and Recovery in the Upper Limb After Stroke; L Carey, D Abbott, G Egan, J Bernhardt, G Donnan; Stroke 2005, 36:625-629; In this study finger tapping ability was used as one of the parameters to quantify recovery following stroke.  Biometrics Ltd finger goniometers were used to measure the range of active flexion-extension movement of the MCP joint of the index finger .

keywords: Gonio XM65 wrist UE biomechanics 2005

Biomechanical Measurement of Painful Wrist by Flexible Electro-goniometry; JH Chang, HY Hsu, FC Su; Journal of Medical and Biological Engineering 2005, 25(1): 33-37; Wrist pain is a common complaint in hand clinics.  Flexible electro-goniometry offers a convenient method to investigate joint kinematics in clinical environment. Biometrics Ltd electrogoniometer was used to measure wrist circumduction in injured subjects.

keywords: Gonio F35 ADU finger UE brain research 2005

Distinct basal ganglia territories are engaged in early and advanced motor sequence learning; S Lehericy, H Benali, PF Van de Moortele, M Pelegrini-Issac, T Waechter, k Ugurbil, J Doyon; Proceedings of the National Academy of Sciences 2005, vol 102, no 35; Biometrics Ltd electrogoniometer and ADU 301 Angle Display Unit were used to measure the amplitude of the subjects’ finger movements before and after training in this study of changes to brain function during the explicit learning of a sequence of finger movements over a month of training.

keywords: Gonio EMG SX230 head neck wrist UE workplace ergonomics 2005

Multi-transducer Data Logger for Worksite Measurement of Physical Workload, YP Liu, HC Chen, CY Chen; Journal of Medical and Biological Engineering 2005, 26(1):12-28; Biometrics Ltd electrogoniometers and EMG sensors were used for onsite measurement of the physical workload of workers, including head and neck of a truck driver and wrist and forearm of a punch press operator.

keywords: Gonio shoulder UE rehabilitation 2004

The effect of limb support on muscle activation during shoulder exercises; M Wise, T Uhl, C Mattacola, A Nitz, W Kiber; Journal of Shoulder and Elbow Surgery 2004, Vol 13, No 6;  The purpose of this study was to determine the difference in demands on glenohumeral musculature during unsupported and supported active range of motion (AROM) shoulder exercises.  Biometrics Ltd electrogoniometer was used to measure shoulder range of motion of each exercise.

keywords: Gonio G35 K100 finger UE orthopedics movement analysis 2004

Motion Enslaving Among Multiple Fingers of the Human Hand; ZM Li, S Dun, D Harkness, T Brininger; Motor Control 2004, 8, 1-15; The purpose of this study was to examine motion enslaving characteristics of multiple fingers during isolated flexion of the distal interphalangeal joints.  Four Biometrics Ltd electrogoniometers connected to a Biometrics Ltd K100 were used to measure the angular motion of the joints.

keywords: Gonio XM110 torsiometer Z110 wrist forearm UE kinesiology 2004

Measurements of wrist and forearm positions and movements: effect of, and compensation for, goniometer crosstalk; GA Hansson, I Balogh, K Ohlsson, S Skerfving; Journal of Electromyography and Kinesiology 2004, 14:355-367; A Biometrics Ltd electrogoniometer and torsiometer were mounted in a jig to simulate the biomechanics of the wrist and forearm.

keywords: Gonio elbow M180 UE PT research sports 2003

The Immediate Effects of a Cervical Lateral Glide Treatment Technique in Patients with Neurogenic Cervicobrachial Pain, MW Coppieters, KH Stappaerts, LL Wouters, K Janssens, Journal of Orthopaedic & Sports Physical Therapy 2003, vol 33, no 7, 369-377; The available ROM during neurodynamic testing is frequently used to appraise the mechanosensitivity and extensibility of the nervous system and in this study was used as the principal outcome measure. Biometrics Ltd electrogoniometer was used to measure the elbow ROM.

keywords: Gonio elbow M180 K100 UE PT research 2003

Aberrant Protective Force Generation During Neural Provocation Testing and the Effect of Treatment in Patients with Neurogenic Cervicobrachial Pain; MW Coppieters, KH Stappaerts, LL Wouters, K Janssens; Journal of Manipulative and Physiological Therapeutics 2003, vol 26, no 2, pp 99-106; Biometrics Ltd electrogoniometers and instrumentation used in this study to analyze whether aberrations in shoulder girdle-elevationforce during neural tissue provocation testing for the median nerve can be demonstrated, and whether possible aberrations can be normalized following cervical mobilization.

keywords: Gonio XM65 M110 bilateral wrist UE ergonomics 2003

Highly Repetitive Work Operations in a Modern Milking System, A Case Study of Wrist Positions and Movements in a Rotary System; M Stal, S Pinzke, GA Hansson, C Kolstrup; Ann Agriculture Environmental Medicine 2003, 10:67-72; Biometrics Ltd electrogoniometers were used to measure bilateral wrist flexion/extension and radial/ulnar deviation in the ergonomics study of milkers while working in a modern rotary milking system.

keywords: Gonio wrist XM65 forearm Z110 Datalogger UE ergonomics 2003

The use of continuous exposure data for predicting CTS in fish processing operators; K Babski-Reeves, L Crumption-Young; Ergonomics 2003, vol 46, no 7, 747-759; Biometrics Ltd electrogoniometers and instrumentation was used in this ergonomics study of 53 workers in a fish processing facility.

keywords: Gonio elbow UE Botox stroke research clinical rehabilitation 2002

Are we underestimating the clinical efficacy of botulinum toxin (type A)? Quantifying changes in spasticity, strength and upper limb function after injections of Botox to the elbow flexors in a unilateral stroke population; A Pandyan, P Vuadens, F van Wijck, S Stark, G Johnson, M Barnes; Clinical Rehabilitation 2002, 16:654-660; Biometrics Ltd electrogoniometer incorporated into a measurement system to quantify the clinical efficacy of botulinum toxin type A in treating elbow spasticity in a unilateral stroke population.

keywords: Gonio elbow M180 K100 UE PT research 2002

Reliability of detecting “onset of pain” and “submaximal pain” during neural provocation testing of the upper quadrant; M Coppieters, K Stappaerts, K Janssens, G Jull; Physiotherapy Research International 2002, 7(3): 146-156; The range of elbow extension in both the laboratory and clinical conditions was measured with Biometrics Ltd electrogoniometer and instrumentation in this study.

keywords: Gonio wrist M110 elbow M180 K100 UE PT research in surgery 2002

Positioning in Anesthesiology: Toward a Better Understanding of Stretch-induced Perioperative Neuropathies, M Coppieters, M Van de Velde, K Stappaerts; Anestiology 2002, 97:75-81; Biometrics Ltd electrogoniometers and instrumentation were used to measure wrist and elbow motion with four variations of the brachial plexus tension test.

keywords: Gonio wrist M110 elbow M180 K100 UE PT research 2001

Shoulder girdle elevation during neurodynamic testing: an assessable sign?, MW Coppieters, KH Stappaerts, FF Staes, DG Everaert; Manual Therapy 2001, 6(2) 88-96; Biometrics Ltd electrogoniometers and instrumentation were used to measure the ROM of the wrist and elbow during this study to measure shoulder girdle elevation force during neural tissue provocation tests of the median nerve.

keywords: Gonio wrist M110 elbow M180 K100 UE PT research 2001

Addition of Test Components During Neurodynamic Testing: Effect on Range of Motion and Sensory Responses, MW Coppieters, KH Stappaerts, DG Everaert, FF Staes; Journal of Orthopedics & Sports Physical Therapy 2001; 31(5): 226-237; In this study to analyze the impact of different components of the neural tissue provocation test for the median nerve on the range of motion of the elbow nd wrist and the sensory responses elicited by the test. Wrist and elbow range of motion was measured with Biometrics Ltd electrogoniometers and instrumentation.

keywords: Gonio XM75 torsiometer Z180 DL1001 P100 UE ergonomics 2000

Effects of progressive levels of industrial automation on force and repetitive movements of the wrist; HJC Coury, JA Leo, S Kumar; International Journal of Industrial Ergonomics 2000, 25:587-595; Biometrics Ltd electrogoniometer and torsiometer were used with a Biometrics Ltd datalogger to record wrist movements of workers in a multinational company for producing office products. A Biometrics Ltd P100 Pinchmeter was used for recording the maximum pinch strength and the job simulated pinch strength.

keywords: Gonio K100 finger UE applied physiology geriatrics 2000

Coactivation of the antagonist muscle does not covary with steadiness in old adults; R Burnett, D Laidlaw, R Enoka; Journal of Applied Physiology 2000, 89:61-71; The purpose of this study was to determine the association between steadiness and activation of the agonist and antagonist muscles during isometric and anisometric contractions. Biometrics Ltd electrogoniometer and K100 amplifier were used measure the index finger abduction/adduction as part of the quantification of the steadiness.

keywords: Gonio wrist DL1001 UE ergonomics 2000

Impact of physical exposure on neck and upper limb disorders in female workers; GA Hansson, I Balogh, K Ohlsson, B Palsson, L Rylander, S Skerving; Applied ergonomics 2000, 31:301-310; Wrist positions and movements were recorded bilaterally, for both the flexion/extension and the deviation angles using Biometrics Ltd electrogoniometers and datalogger.

keywords: Gonio wrist UE ergonomics 1997

Quantifying work load in Neck, Shoulders and wrists in Female Dentists;  I Akesson, GA Hansson, I Balough, U Moritz, S Skerfving; International Archives of Occupational and Environmental Health 1997, 69:461-474 Twelve right-handed female dentists (six with and six without a history of definite neck/shoulder disorders, pair-wise matched for age) were studied when performing authentic dental work. Biometics Ltd electrogoniometers were used to measure the wrist movements.

keywords: Gonio wrist UE clinical measurement validity 1996

A New Technique for the Assessment of Wrist Movement Using a Biaxial Flexible Electrogoniometer; M Rawes, J Richardson, J Dias; Journal of Hand Surgery - British and European Volume 1996 21B(5): 600-603; A new electrogoniometer technique, using a Biometrics ltd electrogoniometer, is described for the measurement of wrist movements, including circumduction, with the results being displayed as figures. Clinical validation was performed and the system found to be highly accurate and reliable.

keywords Gonio wrist torsiometer forearm UE ergonomics 1996

Goniometer Measurement and Computer Analysis of Wrist Angles and Movements Applied to Occupational Repetitive Work; GA Hansson, I Balogh, K Ohlsson, L Rylander,S Skerfving; Journal of Electromyography and Kinesiology 1996, Vol 6, No. 1, pp 23-35 THis study to gain objective and quantitative information concerning both static and dynamic aspects of workload on the wrist in field studies of fish processing industry workers with highly repetitive work and risk of CTD used a Biometrics Ltd biaxial flexible electrogoniometer and datalogger for recording of flexion and deviation angles of the wrist of the dominant hand. In order evaluate forearm rotation a Biometrics Ltd torsiometer, sensitive only to rotation and not influenced by flexion or deviation, was attached to the wrist.

keywords: Gonio wrist UE clinical measurement 1995

Position of the Wrist Associated with the lowest Carpal Tunnel Pressure: Implications for Splint Design; N Weiss, L Gordon, T Bloom, Y So,D Rempel; Journal of Bone and Joint Surgery 1995 Vol 77-A, No. 11, pp 1695-1699 To determine the position of the wrist that results in the lowest carpal tunnel pressure, twenty control subjects and four patients who had carpal tunnel syndrome were evaluated with use of a new, dynamic method that continuously measures carpal tunnel pressure throughout the range of motion of the wrist. A Biometrics Ltd two-axis electrogoniometer was used to measure continuously the flexion or extension angle as well as the radial or ulnar deviation of the wrist.

keywords: Gonio wrist UE ergonomics work eval 1994

Disorders of the Neck and Upper Limbs in Women in the Fish Processing Industry; K Ohlsson, GA Hansson, I Balough,U Stromberg, B Palsson, C Norander, L Rylander, S Skerfving; Occupational and Enviornmental Medicine 1994, 51: 826-832 Wrist angles of the dominant hand were measured for 32 randomly selected women during a total of 40 representative 20 minute work periods. A Biometrics Ltd twin axis electrogoniometer and a Datalogger were used for recording the flexion and extension, and the deviation angles of the wrist. The angular distributions, the angular velocity distributions, and the power spectra, were calculated to characterize the wrist movements during work.

keywords: Gonio elbow UE reliability clinical measurement 1992

Clinical Methods of Goniometry: a Comparative Study; J Goodwin, C Clark, J Deakes, D Burdon, C Lawrence; Disability and Rehabilitation 1992; Vol 14, No.1; pp 10-15 This investigation compared the reliability and interchangeable use of three currently available goniometers - a universal goniometer, a fluid goniometer, and a Biometrics Ltd electrogoniometer. Three consecutive readings of the active range of movement of the right elbow joint were taken from each of 23 healthy female volunteers; three experienced observers each used each type of goniometer on two occasions. Significant intertester differences were found to exist for both the universal and fluid goniometers. However, no significant differences were found between any of the testers with respect to the electrogoniometer. It therefore appears reasonable to suggest that, with respect to reducing intertester differences, the electrogoniometer is preferable.

keywords: Gonio wrist UE relaibility circumduction biomechanics 1991

Dynamic Analysis of Wrist Circumduction: a New Application of the Biaxial Flexible Electrogoniometer; H Ojima, S Miyake, M Kumashiro, H Togami, S Meng, K Suzuki; Clinical Biomechanics 1991; 6: no 4; 221-229 This paper shows the reliability and validity of Biometrics Ltd biaxial electrogoniometric analysis in the quantification of wrist circumduction. The reliability tests demonstrated sufficient accuracy of the device. Also, validity of the measurement was recognized because the tests simulating wrist circumduction and cineradiography revealed that it could accurately detect the angle between the long axis of the forearm and the third metacarpal bone.

© Copyright 2011 All rights reserved