Unique Solutions for Clinical And Research Applications - Biometrics Ltd

Research Using Biometrics Ltd Sensors and Instrumentation
in Pediatrics

keywords: Gonio hip knee LE infants gait physiology 2003

Stumbling corrective responses during treadmill-elicited stepping in human infants; T Lam, C Wolstenholme, M van der Linden, M Pang, J Yang; Journal of Physiology 2003, 553:319-331; This study examined stumbling corrective (tripping) responses to mechanical disturbances applied to the foot during stepping in 33 healthy human infants ages 5-13 months. Biometrics Ltd electrogoniometers were used to measure the hip and knee movement.

keywords: Gonio hip LE infants proprioception gait 2002

Sensory Gating for the initiation of the Swing Phase in Different Directions of Human Infant Stepping; M Pang, J Yang; The Journal of Neuroscience 2002, 22(13):5734-5740; Biometrics Ltd electrogoniometers were used to measure hip position in 37 infants between the ages of 5 and 13 months.

keywords: Gonio hip LE infants physiology 2001

Interlimb co-ordination in human infant stepping; M Pang, J Yang; The Journal of Physiology 2001, 533:617-625; Biometrics Ltd electrogoniometers were used to measure hip movement in twenty-eight infants aged from 4 to 12 months.

keywords: Gonio hip LE infants physiology 1998

Transient Disturbances to One Limb Produce Coordinated, Bilateral Responses During Infant Stepping; J Yang, M Stephens, R Vishram; The Journal of Physiology 1998; Biometrics Ltd electrogoniometers were used to measure the hip movement in infants 3-10 months of age.

keywords: Gonio hip LE infants physiology 1998

Infant stepping: a method to study the sensory control of human walking; J Yang, M Stephens, R Vishram; The Journal of Physiology 1998, 507:927-937; Biometrics Ltd electrogoniometers were used to measure hip movement in infants 10 days to 10 months of age.

keywords: Gonio knee ankle footswithces LE gait pediatrics 1994

The Use of Therapeutic Electrical Stimulation in the treatment of Hemiplegic Cerebral Palsy; M Hazelwood,J Brown, P Rowe, P Salter; Developmental Medicine and Child Neurology, 1994, 36:661-673; Biometrics Ltd electrogoniometers and footswitches were used in this study to evaluate the effect of electrical stimulation of the anterior tibial muscles of children with hemiplegic cerebral palsy on the gait pattern and the range of active and passive lower extremity movement. dorsiflexion of the ankle. Foot switches were placed under the sole and heel of the foot and simultaneously recorded the pattern of contact of the foot with the floor so that the temporal parameters of the gait cycle could be analyzed. The use of electrogoniometers for gait analysis proved successful, and could provide therapists and physicians with a relatively cheap and versatile means of quantitatively monitoring gait pattern and the effects of therapy.

keywords: Gonio hip knee LE clinical measurements gait reliability 1989

Measurement of Joint Motion; A Nicol; Clinical Rehabilitation 1989, 3: 1-9; This paper is about the development of the Biometrics Ltd electrogoniometer and its clinical applications: The device is very lightweight and the electrogoniometers can be worn beneath clothing, so the subject can move without inhibition. ...Tests using angular motion of the hip and knee joints...assessment of gait ...gait of amputees and patients cerebral palsy...assessing the postoperative performance of arthritic patients receiving the Souter-Strathclyde elbow prosthesis. It can be seen that electrogoniometers can provide information otherwise not available in a clinical environment.

© Copyright 2011 All rights reserved