Unique Solutions for Clinical And Research Applications - Biometrics Ltd

Research Using Biometrics Ltd Sensors and Instrumentation
for Clinical Measurements

keywords: DataLINK EMG SX230 stroke LE cycling exercise 2011

Clinical efficacy and prognostic indicators for lower limb pedalling exercise early after stroke: Study protocol for a randomised controlled trial; N Hancock, L Shepstone, P Rowe, PK Myint, V Pomeroy; Trials 2011 12:68 ; Biometrics Ltd DataLink and EMG sensors (SX230) used to measure muscle activity in early stroke patients during stationary bike pedalling exercise.

keywords: DataLOG Analysis sw ACL300 accelerometers vibration bone density LE 2011

Multiple vibration displacements at multiple vibration frequencies stress impact on human femur computational analysis; B Ezenwa, HT Yeoh; Journal Of Rehabilitation Research & Development Volume 48, Number 2, 2011 pages 179 – 190; Biometrics Ltd Accelerometer ACL300 and DataLog with analysis software were used in this study of use of vibration to improve bone density.

keywords: DatalOG force sensors orthodonics 2011

Lip Pressure at Rest and During Function in 2 Groups of Patients with Different Occlusions; D Di Fazio, L Lombardo, A Gracco, P D’Amico, G Siciliani; American Journal Of Orthodontics & Dentofacial Orthopedics January 2011 Pages e1 – e6; Biometrics Ltd DataLOG with analysis software and flexible force sensors were used to measure lip pressure at rest and whilst swallowing.

keywords: DataLINK Goniometers EMG Stroke Spasticity Botulinum Toxin elbow wrist UE 2009

Quantitative Measurement of Poststroke Spasticity and Response to Treatment with Botulinum Toxin a 2 Patient Case Report; E Cousins, A B Ward, C Roffe, L D Rimington, A D Pandyan; Physical Therapy Volume 89 Number 7 p688-697; Biometrics Ltd DataLINK, Goniometers and EMG sensors used as a neurophysiological measure of joint angle and EMG activity in post stroke patients treated for spasticity with Botulinum toxin.

keywords: DataLOG EMGSX230 evoked potentials LE exercise physiology 2008

Hypertherma Impairs Short-Term Memory and Peripheral Motor Drive Transmission; S Racinais, N Gaoua, J Grantham; The Journal Of Physiology 2008 October 1; 586(pt19) p4751-4762; Biometrics Ltd DataLOG and SX230 EMG sensor were used to measure the amplitude of the electrically evoked action potentials in soleus muscle of subjects following exercise in 3 different temperature conditions.

keywords: Gonio sg150 DataLOG Analysis sw knee LE reliability 2008

The reliability of knee joint position testing using electrogoniometry; P Piriyaprasarth, M Morris, A Winter, A Bialocerkowski; Musculoskeletal Disorders 2008, 9:6; This study examined the inter- and intra-tester reliability of knee joint angle measurements using a Biometrics Ltd electrogoniometer.  The clinical utility of electrogoniometry was also addressed. Data was collected using the Biometrics Ltd DataLOG and analyzed using Biometrics Ltd Analysis Software.

keywords: EMG SX230 DataLINK Analysis software LE sports PT 2008

Psychophysiological Effects od Massage-Myofascial Release After Exercise: A Randomized Sham-Control Study; M Arroyo-Morales, N Olea, MM Martinez, A Hidalgo-Lozano, C Ruiz-Rodriguez, L Diaz-Rodriguez; The Journal of Alternative and Complementary Medicine 2008, vol 14, no 10, pp 1223-1229; Biometrics Ltd EMG sensors and DataLINK data acquisition system with analysis software was used to quantify muscle activity in the quadriceps in this study to evaluate the effect of massage on neuromuscular recruitment, mood state, and mechanical nociceptive threshold after high-intensity exercise.

keywords: Gonio finger F35 elbow UE stroke research 2007

Exaggerated interlimb neural coupling following stroke; T Kline, B Schmidt, D Kamper; Brain 2007, 130(1):159-169; Joint angles of the digits of the impaired hand and angle measurements of the elbow joint on the impaired side were measured with Biometrics Ltd electrogoniometers in this study of patterns of interlimb coupling in ten stroke survivors with chronic hand impairment.

keywords: Gonio SG110A DL1001 ankle LE gait 2007

Ankle movements during normal gait evaluated by flexible electrogoniometer; CS Moriguchi, TO Sato, HJC Coury; Revista Brasileria de Fisioterapia 2007, vol 11, no 3; Biometrics Ltd electrogoniometer connected to a Biometrics Ltd datalogger was used to evaluate ankle movements of healthy individuals walking on a treadmill.

keywords: Gonio knee ankle LE physiotherapy 2007

Analysis of the Repeated One-Leg Heel-Rise Test of Ankle Plantar Flexors in Manual Muscle Testing; S Kasahara, J Ebata, M Takahashi; Journal of Physical Therapy Science 2007; 19:251-256; The purpose of this study was to evaluate the repeated one-leg heel-rise test method of ankle plantar flexion in MMT with kinematic measuring devices and EMG.  Biometrics Ltd electrogoniometers were used to monitor ankle and knee movements during the test.

keywords: Gonio SG110 thumb UE ergonomics 2007

Accuracy and feasibility of using an electrogoniometer for measuring simple thumb movements; P Jonsson, P Johnson, M Hagberg; Ergonomics 2007, vol 50, issue 5, pg 647-659; The aim of this study was to determine the accuracy and feasibility of using a Biometrics Ltd electrogoniometer for measuring simple thumb movements and concluded that electrogoniometers have utility for studying thumb movements during mobile phone use and may be used to evaluate other thumb-based input devices.

keywords: Gonio SG150 knee LE movement analysis 2006

Ambulatory measurement of knee motion and physical activity: preliminary evaluation of a smart activity monitor; J Huddleston, A Alaiti, D Goldvasser, D Scarborough, a Freiberg, H Rubash, H Malchau, W Harris, D Krebs; Journal of NeuroEngineering and Rehabilitation; Biometrics Ltd electrogoniometers were used to measure bilateral knee flexion angles for periods of 7-24 hours.

keywords: EMG SX230 DataLOG LE gait neuro rehabilitation 2006

Reliability and Validity of Bilateral Thigh and Foot Accelerometry Measures of Walking in Healthy and Hemiparetic Subjects; K Saremi, J Marehbian, X Yan, JP Regnaux, R Elashoff, B Bussel, B Dobkin; Neurorehabilitation and Neural Repair 2006, 20(2); A biomechanical model was used to compute lower extremity joint kinematics over a short walkway.  Surface EMG was acquired with the (Biometrics Ltd) DataLOG system using 8 (Biometrics Ltd) SX230 EMG sensors and analysed using (Biometrics Ltd) version 3 Analysis Software.

keywords: Gonio M180 knee LE Arthroplasty Orthopedic Surgery 2005

The effect of total knee arthoplasty on joint movement during functional activities and joint range of motion with particular regard to higher flexion users; PJ Rowe, CM Myles, R Nutton; Journal of Orthopedic Surgery 2005, 13(2):131-138; This study used Biometrics Ltd electrogoniometers to evaluate active and functional knee excursion of patients before and after total knee arthroplasty (TKA) to determine whether TKA restores quality of life related to functionsl activities of daily living.

keywords: Gonio G35 finger mcp UE neuro stroke 2005

Motor Impairment and Recovery in the Upper Limb After Stroke; L Carey, D Abbott, G Egan, J Bernhardt, G Donnan; Stroke 2005, 36:625-629; In this study finger tapping ability was used as one of the parameters to quantify recovery following stroke.  Biometrics Ltd finger goniometers were used to measure the range of active flexion-extension movement of the MCP joint of the index finger .

keywords: Gonio sg150 ADU K100 ankle LE physiotherapy 2005

Effects of Age and Sex on the Results of an Ankle Plantar-Flexor Manual Muscle Test; MH Jan, HM Chai, YF Lin, JCH Lin, LY Tsai, YC Ou, DH Lin; Physical Therapy October 2005, vol 85, no 10; The ability to perform 20 or more one-leg heel-rises is considered a “normal” grade for muscle strength of the ankle plantar flexors, regardless of age and strength.  Because muscle strength is closely related to age and sex, the “normal” test criterion was re-evaluated in different groups categorized by age and sex. Biometrics Ltd electrogoniometers and instrumentation was used to measure the angle of ankle plantar flexion.

keywords: Gonio XM65 wrist UE biomechanics 2005

Biomechanical Measurement of Painful Wrist by Flexible Electro-goniometry; JH Chang, HY Hsu, FC Su; Journal of Medical and Biological Engineering 2005, 25(1): 33-37; Wrist pain is a common complaint in hand clinics.  Flexible electro-goniometry offers a convenient method to investigate joint kinematics in clinical environment. Biometrics Ltd electrogoniometer was used to measure wrist circumduction in injured subjects.

keywords: Gonio SG150 EMG SX230 DataLINK knee LE applied physiology 2005

Age Differences in knee extension power, contractile velocity, and fatigability; J Petrella, JS Kim, C Tuggle, S Hall, M Bamman; Journal of Applied Physiology 2005, 98:211-220; The purposes of this study were to examine age and gender differences in knee extension strength, power, and fatigue using open- and closed-chain testing procedures.  Knee position and flexion/extension movement was measured using Biometrics Ltd electrogoniometers and neural activity of the right knee extensors was measured for each of three superficial quadriceps muscles using Biometrics Ltd EMG sensors.  EMG were digitized at 1000 Hz and electrogoniometer inputs at 500 Hz, and data from each input were analyzed simultaneously using Biometrics Ltd DataLINK with software version 2.0.

keywords: Gonio SG150 SG110A knee ankle LE biomechanics sports 2005

Effects of Passive Ankle and Knee Joint Motions on the Length of Fascicle and Tendon of the Medial Gastrocnemius; T Wakahara, J Ushiyama, H Kanehisa, Y Kawakami, T Fukunaga; International Journal of Sport and Health Science 2005, vol 3, 75-82; Biometrics Ltd electrogoniometers were used to measure the angles of ankle (SG110A) and knee (SG150)  joints in this study of lower extremity biomechanics.

keywords: Goniometer Ankle Diabetes exercise therapy LE 2002

The Effects of Range of Motion Therapy on the Plantar Pressures of patients with Diabetes Mellitus; J R Goldsmith, R H Lidtke, S Shott; Journal Of American Podiatric Medical Association Vol 92 No 9 October 2002; Biometrics Ltd goniometers used to measure ankle joint position prior to and during exercise therapy to increase joint mobility and reduce plantar pressures in diabetic patients.

keywords: Gonio elbow UE Botox stroke research clinical rehabilitation 2002

Are we underestimating the clinical efficacy of botulinum toxin (type A)? Quantifying changes in spasticity, strength and upper limb function after injections of Botox to the elbow flexors in a unilateral stroke population; A Pandyan, P Vuadens, F van Wijck, S Stark, G Johnson, M Barnes; Clinical Rehabilitation 2002, 16:654-660; Biometrics Ltd electrogoniometer incorporated into a measurement system to quantify the clinical efficacy of botulinum toxin type A in treating elbow spasticity in a unilateral stroke population.

keywords: Gonio elbow M180 K100 UE PT research 2002

Reliability of detecting “onset of pain” and “submaximal pain” during neural provocation testing of the upper quadrant; M Coppieters, K Stappaerts, K Janssens, G Jull; Physiotherapy Research International 2002, 7(3): 146-156; The range of elbow extension in both the laboratory and clinical conditions was measured with Biometrics Ltd electrogoniometer and instrumentation in this study.

keywords: Gonio M180 bilateral knee LE reliability biomechanics arthritis 2001

Movement of the knee in osteoarthritis: the use of electrogoniometry to assess function; C Walker; Journal of Bone and Joint Surgery 2001; 83-B: 195-198; This study 50 patients with knee osteoarthritis using Biometrics Ltd electrogoniometers concluded: “Electrogoniometry is relatively inexpensive, can be performed in a normal clinical setting with minimal inconvenience to the patient, and may prove to be a valuable objective tool for comparative evaluation of different prostheses or surgical techniques for total knee replacement.”

keywords: Gonio knee LE anatomy reliability 2000

Verification of selected anatomical landmarks used as reference points for universal goniometer positioning during knee joint mobility range measurements; P Szuic, J Lewandowski, B Marecki; Medical Science Monitor 2000, 7(2): 312-315; In this study Biometrics Ltd electrogoniometer was used as the accurate and reliable measurement to validate knee position measurements with a universal goniometer.

keywords: Gonio wrist UE clinical measurement validity 1996

A New Technique for the Assessment of Wrist Movement Using a Biaxial Flexible Electrogoniometer; M Rawes, J Richardson, J Dias; Journal of Hand Surgery - British and European Volume 1996 21B(5): 600-603; A new electrogoniometer technique, using a Biometrics ltd electrogoniometer, is described for the measurement of wrist movements, including circumduction, with the results being displayed as figures. Clinical validation was performed and the system found to be highly accurate and reliable.

keywords: Gonio wrist UE clinical measurement 1995

Position of the Wrist Associated with the lowest Carpal Tunnel Pressure: Implications for Splint Design; N Weiss, L Gordon, T Bloom, Y So,D Rempel; Journal of Bone and Joint Surgery 1995 Vol 77-A, No. 11, pp 1695-1699 To determine the position of the wrist that results in the lowest carpal tunnel pressure, twenty control subjects and four patients who had carpal tunnel syndrome were evaluated with use of a new, dynamic method that continuously measures carpal tunnel pressure throughout the range of motion of the wrist. A Biometrics Ltd two-axis electrogoniometer was used to measure continuously the flexion or extension angle as well as the radial or ulnar deviation of the wrist.

keywords: Gonio knee ankle footswithces LE gait pediatrics 1994

The Use of Therapeutic Electrical Stimulation in the treatment of Hemiplegic Cerebral Palsy; M Hazelwood,J Brown, P Rowe, P Salter; Developmental Medicine and Child Neurology, 1994, 36:661-673; Biometrics Ltd electrogoniometers and footswitches were used in this study to evaluate the effect of electrical stimulation of the anterior tibial muscles of children with hemiplegic cerebral palsy on the gait pattern and the range of active and passive lower extremity movement. dorsiflexion of the ankle. Foot switches were placed under the sole and heel of the foot and simultaneously recorded the pattern of contact of the foot with the floor so that the temporal parameters of the gait cycle could be analyzed. The use of electrogoniometers for gait analysis proved successful, and could provide therapists and physicians with a relatively cheap and versatile means of quantitatively monitoring gait pattern and the effects of therapy.

keywords: Gonio ankle LE podiatry 1994

Single Case Experiment to Investigate a Short Term Stretching Programme for Ankle Equinus; K Rome, A Clark; British Journal of Podiatric Medicine 1994, 49(2): 19-23; Biometrics Ltd electricgoniometers were used in this study is to evaluate a short term stretching programme for ankle equinus, using a high load, brief stretch tenique. The single case study has demonstrated the flexible electrogoniometer as a reliable instrument which is easy to use in the clinical setting.

keywords: Gonio ankle LE clinical measurement biomechanics reliability 1993

Reliability of Hindfoot Goniometry when Using a Flexible Electrogoniometer; P Ball, G Johnson; Clinical Biomechanics 1993; 8: 13-19 This paper describes the use of an Biometrics Ltd electrogoniometer for clinical assessment of subtalar motion and examines the important aspects of the clinical procedure.

keywords: Gonio elbow UE reliability clinical measurement 1992

Clinical Methods of Goniometry: a Comparative Study; J Goodwin, C Clark, J Deakes, D Burdon, C Lawrence; Disability and Rehabilitation 1992; Vol 14, No.1; pp 10-15 This investigation compared the reliability and interchangeable use of three currently available goniometers - a universal goniometer, a fluid goniometer, and a Biometrics Ltd electrogoniometer. Three consecutive readings of the active range of movement of the right elbow joint were taken from each of 23 healthy female volunteers; three experienced observers each used each type of goniometer on two occasions. Significant intertester differences were found to exist for both the universal and fluid goniometers. However, no significant differences were found between any of the testers with respect to the electrogoniometer. It therefore appears reasonable to suggest that, with respect to reducing intertester differences, the electrogoniometer is preferable.

keywords: Gonio wrist UE relaibility circumduction biomechanics 1991

Dynamic Analysis of Wrist Circumduction: a New Application of the Biaxial Flexible Electrogoniometer; H Ojima, S Miyake, M Kumashiro, H Togami, S Meng, K Suzuki; Clinical Biomechanics 1991; 6: no 4; 221-229 This paper shows the reliability and validity of Biometrics Ltd biaxial electrogoniometric analysis in the quantification of wrist circumduction. The reliability tests demonstrated sufficient accuracy of the device. Also, validity of the measurement was recognized because the tests simulating wrist circumduction and cineradiography revealed that it could accurately detect the angle between the long axis of the forearm and the third metacarpal bone.

keywords: Gonio hip knee LE clinical measurements gait reliability 1989

Measurement of Joint Motion; A Nicol; Clinical Rehabilitation 1989, 3: 1-9; This paper is about the development of the Biometrics Ltd electrogoniometer and its clinical applications: The device is very lightweight and the electrogoniometers can be worn beneath clothing, so the subject can move without inhibition. ...Tests using angular motion of the hip and knee joints...assessment of gait ...gait of amputees and patients cerebral palsy...assessing the postoperative performance of arthritic patients receiving the Souter-Strathclyde elbow prosthesis. It can be seen that electrogoniometers can provide information otherwise not available in a clinical environment.

keywords: Gonio hip knee bilateral LE biomechanics gait 1988

Flexible Goniometer Computer System for the Assessment of Hip Function - The Clinical Biomechanics Award 1988; P Rowe, A Nicol, I Kelly; Clinical Biomechanics 1988, 4:68-72; Biometrics Ltd flexible electrogoniometers were used to record the motion of both hips and knees in total hip replacement patients. Four flexible electrogoniometers are used to measure the flexion-extension angles of both hips and both knees. The electrogoniometer system has proved capable of quantifying the functional status of hip replacement patients simply and economically within the clinical environment.

© Copyright 2011 All rights reserved